KCT301 Digital Coating Thickness Gauge with Bluetooth Data Transfer
KCT301 Digital Coating Thickness Gauge with Bluetooth Data Transfer
Regular price $299.00

Coating Thickness Gauge

 

This coating thickness gauge is a portable measuring instrument that measures the thickness of coatings, it is scan fast, highly accurate, nondestructive.

Application: the coating thickness gauge applied to a variety of measurement filed, widely used in testing fields such as manufacturing, metal processing industry, chemical industry, and commodity inspection. It is an essential instrument for material protection professionals, for coating thickness measuring of electroplating layer, paint layer, fire protection layer, anticorrosion layer, enamel layer, aluminum tile, copper tile, pasteurized alloy tile, phosphorization layer, paper thickness measurement, etc.

This coating thickness gauge measures non-magnetic coating layers covered on magnetic substrate. Such as: non-magnetic (aluminum, chrome, copper, enamel, paint) covered on magnetic substrate (steel, alloy and magnetic stainless steel), also for insulating non-conductive coatings layers covered on non magnetic substrate . Such as: (enamel, rubber, paint, plastic) covered on conductive substrate (aluminum, brass, zinc and nonmagnetic stainless steel)

Practical information show on display

No. Name On Display
1 Test method nFe Eddy method (for N probe)
Fe Magnetic method ( for F probe)
2 Exceeding ▲▼ Exceeding the limit
3 Test result 0.0-99.9
100-1250μm
4 Measuring Mode Single single measuring mode
Contin. continuing measuring mode
5 Storage 00-100 100 measurements for each file
6 File name 00-05 Total 6 file
7 Unit μm mil
mm inch
8 Battery indicator
TECHNICAL DATA  
Measuring Range Standard 0~1250μm (option probe F10 Max 10000μm)
Resolution 0.1μm/1μm
Working Principle Magnetic & Eddy
Substrate FE / NFe base, depends on probes
Accuracy ± (2%H+1)μm Note: H is thickness reading
Measuring condition Smallest Measuring Diameter

for F1 probe: Φ7mm. for N1 probe:φ5mm

Smallest radius of curvature

F1: for convex surface: 1.5mm

N1: for convex surface: 3mm

Smallest thickness of Base

for F1 probe : 0.5mm. for N1 probe: 0.3mm
Display 128x64 LCD with backlight
Memory 600 values
Unit Switch Metric (μm) Imperial (mil)
Working Temperature Operation Temp. :-10°C~50°C Storage Temp. :-30°C-70°C
humidity 20%~90%RH
Power AA battery 2pcs (Non-aviation transport)
Size 154x77x32mm
Weight 340g
Standard Probe F1 probe or N1 probe for selection
MAIN FEATURE  
  1. Two thickness measurement methods: magnetic and eddy current
  2. A variety of probes can be used (F1, F1/90°N1, F10);
  3. Two measuring modes are available: continuing measuring mode(CONTINUE)and single measuring mode(SINGLE)
  4. (Optional) The Bluetooth module can be embed for wireless connection with a printer and wireless transfer via Bluetooth adaptor.
  5. One-click data sending function to send measurement results to statistical software or EXECL by Bluetooth adaptor. (optional)
  6. Five statistic values:mean value(MEAN), max. value(MAX), min. value(MIN), numbers of measuring(NO.), standard deviation(S.DEV)
  7. Two methods can be used to calibrate the gauge, and the system error of the probe can be corrected by use of basic calibrating method
  8. Deletion function: delete the single questionable data occurring in measuring, as well as all of the data in memory area to perform the new measuring
  9. Limits can be set: automatic alarm for measured values exceeding the limits;
  10. With battery indicator
  11. Buzzing Indication in the course of operation
  12. With the function of error warning, error warning can be carried out through display or buzzing
  13. Two shut down modes are available: manual shut down mode and automatic shut down mode
STANDARD DELIVERY  
ITEM QTY
Main Unit 1 PC
F1 probe 1 PC (or change to N1 probe instead)
Standard Calibration Piece (5 pcs) 1 SET
Substrate 1 PC (Fe or NFe according to probe)
User Manual 1 PC
Instrument Case 1 PC
Warranty 2 Years
RELATED OPTIONAL ITEMS  
 

F1 probe - Fe base

Measuring range: 0~1250μm Accuracy: Two-point calibration (μm): ±((1-3)%H+1)
F1 probe measures for Non-magnetic coatings over magnetic coatings.
The substrate are Ferrous, the coating are Non-Ferrous or non-magnetic including insulating layer.

 

N1 probe - nFe base

Measuring range: 0~1250μm Accuracy: Two-point calibration (μm): ±((1-3)%H+1.5)
N1 probe measures for Non-conductive coatings over Non-magnetic substrate. The substrate are Non-Ferrous and conductive, the coating are insulating material.

 

F1/90°probe - Fe base

Measuring range: 0~1250μm Accuracy: Two-point calibration (μm): ±((1-3)%H+1)
F1/90° measures non-magnetic coating layers covered on magnetic substrate, it is for measuring the coating thickness of wall in holes.

Sample are required: Min curvature radius (mm): flat surface. Min Diameter: (7. Min thickness of substrate: 0.5mm

 

F10 probe - Fe base (Large range)

Measuring range: 0~10000μm Accuracy: Two-point calibration (μm): ±((1-3)%H+10)
measures non-magnetic coating layers covered on magnetic substrate
Sample are required: Min curvature radius (mm): 10mm. Min Diameter: (40. Min thickness of substrate: 2mm

 

Standard coating thickness calibration pieces

Standard thickness value between 0~1250μm 5pcs/set, include metal or aluminum base (Fe or nFe)

 

Standard coating thickness calibration pieces (Large range)

Standard thickness value between 0~10000μm 5pcs/set, include include metal or aluminum base (Fe or nFe)

For all orders exceeding a value of 100USD shipping is offered for free.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item, only in the case of:

– Received the wrong item.
– Item arrived not as expected (ie. damaged packaging).
– Item had defects.
– Over delivery time.
– The shipper does not allow the goods to be inspected before payment.

The returned product(s) must be in the original packaging, safety wrapped, undamaged and unworn. This means that the item(s) must be safely packed in a carton box for protection during transport, possibly the same carton used to ship to you as a customer.

Recently Viewed

Don't forget! The products that you viewed. Add it to cart now.

People Also Bought

Here’s some of our most similar products people are buying. Click to discover trending style.